Design and Manufacturing according to CE, ATEX Standard
Introduction
P Series Coriolis Mass Flow Meter is defined as P Series Mass Flow Meter with Flow Accuracy Rate of 0.1,
consisting of "P Series Mass Flow Sensor" and "DPT Transmitter"
Features
- Double U or Double C Measuring Tube Design
- Gas Measurement Available
- Easy Installation, no need rectifier, filter parts, no special requirements for installing direct pipe section.
- High Stability, no need deploying frequent disassemble calibration
- Allow Low-Range Run, reducing pressure loss and energy consumption & waste
- Integrated Installation saving installation cost
- High Stability, expert in "Custody Transfer / Fiscal Metering of Oil & Gas"
General Technical Parameters (For More Details, please contact Tosilon)
Max. Mass Flow Rate | Sensor Type | Mass Flow (kg/h) | Volumetric Flow[1] (l/h) |
P10 | 1500 | 1500 | |
P15 | 4500 | 4500 | |
P20 | 9450 | 9450 | |
P25 | 25500 | 25500 | |
P50 | 94500 | 94500 | |
P80 | 240000 | 240000 | |
P100 | 540000 | 540000 | |
P150 | 825000 | 825000 | |
P200 | 1650000 | 1650000 | |
P250 | 2700000 | 2700000 | |
Mass Flow Accuracy[2] | 15:1, Within Measure Ratio[3] | ±0.1% | |
15:1, Beyond Measure Ratio | ± (Zero Stability / Instant Flow Rate) x 100% | ||
Volume Flow Accuracy[2] | Whole Measure Range ±0.15± (Zero Stability / Instant Flow Rate) x 100% | ||
Repeatability | 15:1, Within Measure Ratio | ±0.05% | |
15:1, Beyond Measure Ratio | ±1/2 (Zero Stability / Instant Flow Rate) x 100% | ||
Zero Stability | Sensor Type | kg/h | |
P10 | 0.10 | ||
P15 | 0.30 | ||
P20 | 0.63 | ||
P25 | 1.70 | ||
P50 | 6.30 | ||
P80 | 16.0 | ||
P100 | 36.0 | ||
P150 | 55.0 | ||
P200 | 110.0 | ||
P250 | 180.0 |