Coriolis Mass Flowmeter for Custody Transfer Metering of Oil, Gas

Tosilon Coriolis Mass Flowmeter for Custody Transfer Metering of Oil, Gas (Ex Approved)Design and Manufacturing according to CE, ATEX StandardIntroductionP Series Coriolis Mass Flow Meter is defined as P Series Mass Flow Meter with Flow Accuracy Ra

Technical Feature

  • Shanghai, China
  • 600 Sets/Month
  • L/C, T/T
  • ≤±0.1%
  • Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas, Crude Oil
  • DN100-500
Send Standard Inquiry Add Inquiry List

0 Add Favorite

$10~2

PRIMARY PARAMETERS

Model NO.
P Series
Measuring Media
Liquid
Measuring Principle
Coriolis Force
Measurement Object
Closed Pipeline
Certification
GB, CE
Flow Meter Size
Dn10 to Dn250
Medium Available
Liquid, Gas
Accuracy Class
0.1%F.S Under 15
Repeatability
0.05% Under 15
Process Temperature
-40 to 350 Deg. C
Process Pressure
0 - 1.6 MPa
Explosion-Proof
Ex Ib Iic T6
Protection Class
IP67 (Split Type)
Wetted Part
Ss316L, as Required
Output
4-20mA, 0-10kHz, Hart / Modbus
Trademark
Tosilon
Transport Package
International Export Wooden Packing, Water Proof
Specification
Based on Actual Order
Origin
Shaanxi
HS Code
902610000

DETAIL DESCRIPTION

Tosilon Coriolis Mass Flowmeter for Custody Transfer Metering of Oil, Gas (Ex Approved)
Design and Manufacturing according to CE, ATEX Standard

Introduction
P Series Coriolis Mass Flow Meter is defined as P Series Mass Flow Meter with Flow Accuracy Rate of 0.1,
consisting of "P Series Mass Flow Sensor" and "DPT Transmitter"
Coriolis Mass Flowmeter for Custody Transfer Metering of Oil, Gas
Coriolis Mass Flowmeter for Custody Transfer Metering of Oil, Gas

Features
-    Double U or Double C Measuring Tube Design
-    Gas Measurement Available
-    Easy Installation, no need rectifier, filter parts, no special requirements for installing direct pipe section.
-    High Stability, no need deploying frequent disassemble calibration
-    Allow Low-Range Run, reducing pressure loss and energy consumption & waste
-    Integrated Installation saving installation cost
-    High Stability, expert in "Custody Transfer / Fiscal Metering of Oil & Gas"

Coriolis Mass Flowmeter for Custody Transfer Metering of Oil, Gas

General Technical Parameters (For More Details, please contact Tosilon)
Max. Mass Flow RateSensor TypeMass Flow (kg/h)Volumetric Flow[1] (l/h)
P1015001500
P1545004500
P2094509450
P252550025500
P509450094500
P80240000240000
P100540000540000
P150825000825000
P20016500001650000
P25027000002700000
Mass Flow Accuracy[2]15:1, Within Measure Ratio[3]±0.1%
15:1, Beyond Measure Ratio± (Zero Stability / Instant Flow Rate) x 100%
Volume Flow Accuracy[2]Whole Measure Range ±0.15± (Zero Stability / Instant Flow Rate) x 100%
Repeatability15:1, Within Measure Ratio±0.05%
15:1, Beyond Measure Ratio±1/2 (Zero Stability / Instant Flow Rate) x 100%
 
Zero StabilitySensor Typekg/h
P100.10
P150.30
P200.63
P251.70
P506.30
P8016.0
P10036.0
P15055.0
P200110.0
P250180.0

P Series Coriolis Flow Meter
Coriolis Mass Flowmeter for Custody Transfer Metering of Oil, Gas

Coriolis Mass Flowmeter for Custody Transfer Metering of Oil, Gas
 
For more information, please contact Tosilon
Your Global Partner for Automation
www.tosilon.com

Coriolis Mass Flowmeter for Custody Transfer Metering of Oil, Gas
 

Send Consultations Sending PUBLIC question and getting response from the supplier

Send Only your public informations will be shown

All Consultations

Products From Supplier

Liquid Radar Level Gauge for Fuel, Oil, LPG, Ethanol Tank

Tosilon Liquid Radar Level Gauge for Fuel, Oil, LPG, Ethanol Tank (Ex Approved)Design and Manufacturing according to ATEX StandardIntroduction    Guided wave radar meter is a gauge based on time stroke principle, the radar wave is running at speed

Rtd Resistance Signal Type Intrinsic Safety Barrier (ATEX Approved)

Tosilon RTD Resistance Signal Type Intrinsic Safety Barrier (ATEX, FCC, Ex Approved)Design and Manufacturing according to ATEX, UL StandardIntroductionThis type of isolated safety barrier transmits RTD resistance signals from hazardous area to safe

Analog Voltage Input Isolated Intrinsic Safety Barrier (ATEX Approved)

Tosilon Analog Voltage Input Isolated Intrinsic Safety Barrier (ATEX, FCC, Ex Approved)Design and Manufacturing according to ATEX, UL StandardIntroduction  This type of isolated safety barrier transmits thermocouple signals from hazardous area to

Thermocouple Input Type Isolated Intrinsic Safety Barrier (ATEX Approved)

Tosilon Thermocouple Input Type Isolated Intrinsic Safety Barrier (ATEX, FCC, Ex Approved)Design and Manufacturing according to ATEX, UL StandardIntroduction  This type of isolated safety barrier transmits thermocouple signals from hazardous area

Analog Current Output (Isolated) Intrinsic Safety Barrier (ATEX Approved)

Tosilon Analog Current Output (Isolated) Intrinsic Safety Barrier (ATEX, FCC, Ex Approved)Design and Manufacturing according to ATEX, UL StandardIntroductionThis type of isolated safety barrier transmits RTD resistance signals from hazardous area t