Product Description:
GCR closed-loop crystallizers are used for constant crystallization of un-crystallized PET regrinds or pellets. Processed materials can then be dried and dehumidified directly. This system mainly consists of heating elements, insulated hopper and agitator screw mixing device. After un-crystallized PET materials fed into the hopper, the system starts crystallization and agitator starts blending to prevent formation in lumps. Crystallized materials can be conveyed to material storage bin or into drying hopper.
Features:
Standard configuration
1. Fixed speed of agitator makes materials not lump together during the crystallization.
2. Simplify and improve drying efficiency.
3. Materials can be dried under high temperature to raise drying efficiency.
4. Cyclone dust collector is standard, which is applied to dust-rich place. Can effectively reduce the load on air-return filter, and extend the life of the filter to reduce the number of times of filter cleaning.
5. With double overheat protectors, it can reduce the possibility of either mechanical or man-made problems.
6. Equipped with manual valve.
7. Equipped with material level switch, which can detect material levelaccurately and make operation reliable.
Accessory option:
1. Can collocate with dehumidifier to fulfill dehumidification directly.
2. Auto loader, hopper receiver, magnetic base, suction box are optional fo material conveying.
3. Optional conveying screw (fixed or variable speed) for quantitative output of crystallized material.
Model GCR- | 160U | 450U | 900U | 1600U | 2500U |
Hopper Capacity (kg) | 100 | 300 | 600 | 1000 | 1500 |
Heater Power (kw) | 12 | 24 | 48 | 86 | 128 |
Blending Motor Power (kw) | 0.25 | 1.1 | 1.5 | 1.5 | 2.2 |
Blower Power (kw) | 0.55 | 2.2 | 3 | 8.5 | 15 |
Max. Throughput (kg/hr) | 50 | 150 | 300 | 500 | 750 |
Dimensions | |||||
H(mm) | 2380 | 3850 | 4450 | 5350 | 5670 |
W(mm) | 1040 | 1440 | 1930 | 2190 | 2350 |
D(mm) | 1140 | 2370 | 2890 | 3570 | 4050 |
Weight(kg) | 230 | 500 | 870 | 2290 | 2790 |
Note: Above max. processing capacity is based on uncrystallized PET material of 0.85kg/L in density and 3~5mm in diameter.