100m,120m,135m,140m,150m,160m,170m,180m,220m,240m,250m,270m,400m,430m,450m,500m,550m,600m gravel suction tap water rotor pump

The motor winding is the polyethylene waterproof nylon sheathed wire.

Technical Feature

  • Shanxi, China (Mainland)
  • JINLONG
  • WQ
  • Centrifugal Pump
  • Multistage Pump, Single-stage Pump
  • Water, Oil, Mud, Sewage, Liquid, River Sand
Send Standard Inquiry Add Inquiry List

0 Add Favorite

$101~500

PRIMARY PARAMETERS

Place of Origin
Shanxi, China (Mainland)
Brand Name
JINLONG
Model Number
WQ
Theory
Centrifugal Pump
Structure
Multistage Pump, Single-stage Pump
Usage
Water, Oil, Mud, Sewage, Liquid, River Sand
Power
1.1, 2.2, 4, 7, 11, 15, 30, 50, 100, 160, 200, 250, 300, 350, 410kw
Standard or Nonstandard
Standard
Fuel
Electric
Pressure
High Pressure, Middle Pressure, Low Pressure
Application
Sewage, Submersible
Flow
6, 10, 20, 30, 50, 60, 80, 100, 150, 200, 300, 400, 500, 600m3/h
Head
10, 20, 30, 50, 70, 100, 150, 200, 300, 400, 500, 550, 600, 650, 680m
Voltage
3ph, 220V, 380V, 440V, 660V, 1140V
Outlet diameter
25, 40, 50, 65, 80, 100, 150, 200, 300, 400mm
Feature
High head, Large capacity
Material
Cast iron, Stainless steel
Material of impeller
Cast iron, stainless steel, cast steel
PH of dielectric
4, 5, 6, 7, 8, 9, 10
Application range
Mine, Sewage, Irrigation, Chemical plant, Construction Site
Certificate
ISO9001

DETAIL DESCRIPTION

100m,120m,135m,140m,150m,160m,170m,180m,220m,240m,250m,270m,400m,430m,450m,500m,550m,600m gravel suction tap water rotor pump

 

600m pump

 

 

 

Product Description

1. Our WQ downdraft submersible sewage pump, it is used to pumping mud of the sewage and sludge under all kinds of bad environment, the motor is submersible three phase asynchronous, small, and easily assemble, reliable durability

2. Rated frequency: 50Hz / 60Hz

3. Rated Voltage: 3ph, 220V, 380V, 440V, 660V, 1140V±5%

4. The pump is downdraft, so it can drainage of surface water in working face

5. The motor is submersible three phase asynchronous, small, and easily assemble, reliable durability

6. The maximum flow is 600m³/h

7. The largest head can be 680m

8. The maximum motor power can be 410kw

9. The volumetric ratio of the solids in the Conveying medium is less than 2%, the maximum density of the conveying medium is 1.2*10³kg/m³

10. the PH of the conveying medium is 4-10

11. The temperature of the conveying medium is less than 40℃(except hot water pump)

12. The material is cast iron, 304, 316, 316L stainless steel

13. All the pump can be made to hot water pump

 

 

 

 Product Feature

1. The WQ downdraft sewage pump is combined by Submersible three phase asynchronous motor and sewage pump

 

2. The motor winding is the polyethylene waterproof nylon sheathed wire. The motor cavity and the Sealed cavity is filled with No.10 mechanical oil or No.25 transformer oil, till submerging the upper bearing when the pump is vertical. The bearing of the motor is centripetal ball, Easy disassembly and assembly, Convenient maintenance.

 

3. The small flow water pump is Centrifugal type or vortex type, it is used to pumping common sewage, high-lift drainage in the project; the large flow water pump is double channel without clogging or mixed flow structure, it is used for the wastewater recycling of coal washery, slime pumping and agricultural river irrigation.

 

 

 

600m pump

 

 

 

600m pump

 

 

 

600m pump

 

 

 

600m pump

 

 

 

600m pump

600m pump

600m pump

600m pump

600m pump

 

 

 

600m pump

600m pump

 

 

 

600m pump

 

 

 

600m pump

 

 

 

Product Specifications

Model No.Pump capacity
(m³/h)
Pump head
(m)
Power
(kw)
WQ6-23-1.1-X6231.1
WQ6-120-7.5-X61207.5
WQ10-34-2.2-X10342.2
WQ12.5-40/2-3-X12.5403
WQ12.5-430-45-X12.543045
WQ15-25-2.2-X15252.2
WQ15-180-18.5-X1518018.5
WQ20-26-3-X20263
WQ20-270-45-X2027045
WQ30-10-2.2-X30102.2
WQ30-220-45-X3022045
WQ40-40-9.2-X40409.2
WQ40-100-18.5-X4010018.5
WQ50-10-3-X50103
WQ50-170-45-X5017045
WQ60-60-18.5-X606018.5
WQ60-140-45-X6014045
WQ70-10-4-X70104
WQ70-120-45-X7012045
WQ80-10-7.5-X80107.5
WQ80-100-45-X8010045
WQ100-12-7.5-X100127.5
WQ100-70-37-X1007037
WQ120-40-30-X1204030
WQ120-60-37-X1206037
WQ150-15-13-X1501513
WQ150-60-45-X1506045
WQ160-46-37-X1604637
WQ200-15-18.5-X2001518.5
WQ200-40-37-X2004037
WQ250-15-30-X2501530
WQ300-12-22-X3001222
WQ300-30-45-X3003045
WQ350-20-45-X3502045
WQ400-15-37-X4001537
WQD15-300/7-451530045
WQD20-180/4-302018030
WQD20-600/13-10020600100
WQD25-180/4-372518037
WQD25-395/9-752539575
WQD30-160/4-373016037
WQD30-600/14-16030600160
WQD50-135/3-375013537
WQD50-650/14-22050650220
WQD60-100/3-306010030
WQD60-500/11-18060500180
WQD70-100/2-377010037
WQD70-650/12-35070650350
WQD80-100/2-458010045
WQD80-680/12-41080680410
WQD100-60-301006030
WQD100-600/12-410100600410
WQD120-80/2-551208055
WQD120-500/10-410120500410
WQD150-70/2-5515070410
WQD150-400/9-41015040075
WQD160-80/2-7516080220
WQD160-220/5-220160220220
WQD200-45-452004545
WQD200-300/9-410200300410
WQD250-40-552504055
WQD250-290/5-410250290410
WQD300-35-553003555
WQD300-200/4-410300200410
WQD320-28-553202855
WQD350-20-4350204
WQD350-200/4-410350200410
WQD400-15-374001537
WQD400-180/4-410400180410
WQD500-15-455001545
WQD500-120-350500120350
WQD600-10-456001045
WQB15-9-1.11591.1
WQB7-15-1.17151.1
WQB12-15-1.512151.5
WQB20-18-2.220182.2
WQB50-7-2.25072.2
WQB60-9-36093
WQB50-15-450154
WQB18-32-5.518325.5
WQB45-22-7.545227.5
WQA50-40-11504011
WQA15-80-13158013
WQA150-20-18.51502018.5
WQA50-80-22508022
WQA150-40-301504030
WQA200-30-302003030
WQA300-12-303001230
WQA300-20-373002037
WQA100-60-371006037
WQ6-16-0.756160.75
WQ25-12-1.525121.5
WQ35-20-335203
WQ18-32-418324
WQ60-10-460104
WQ65-15-5.565155.5
WQ100-12-7.5100127.5
WQ50-7-15-1.150151.1
WQ65-32-10-2.265102.2
WQ80-45-9-2.28092.2
WQ100-60-9-310093
WQ150-150-7-5.515075.5
WQ200-400-25-452002545
WQ250-600-15-452501545
WQ300-800-12-453001245
WQ250-600-30-902503090
WQ300-950-20-903002090

 

 

 

How to choose the most suitable water pump

1. The listing head in the nameplate or specifications of the water pump is rated head, the corresponding flow is rated flow (the efficient of the pump is the largest based on this ratio), when the rotational speed of the water pump is fixed, the head of the pump is not constant, it decreases with the increase of water flow of the pump, the shaft power of the pump and the current of the motor increases with the increase of water flow of the pump, if the actual flow exceeds 1.2 times of the rated flow, the motor will be burned easily.

 

2. The flow is the amount of the liquid delivered by the pump in the unit time(volume or weight), the head is the energy increment of the unit weight liquid pumped by the pump from the pump inlet (the pump inlet flange) to the pump outlet, it is the Pumping liquid column height, it is called meter, the suitable head of the pump is very important to the service life of the pump.

 

3. Different pump, different application, usually the actual head can reach 0.9-1.05 times of the rated head, the actual flow can reach 0.7-1.2 times of the rated flow.

 

Tell us your requirements or working conditions, we will satisfy you!

 

Related Accessories of the water pump

Submersible Sewage Pump

Submersible Mine Pump

Submersible Well Pump

Submersible Mud Pump

Control Cabinet

Cable

Pipe

Pump Accessories

Send Consultations Sending PUBLIC question and getting response from the supplier

Send Only your public informations will be shown

All Consultations

Shanxi Shenlong Pump Co., Ltd.

pump,water pump,submersible pump,sewage pump,mud pump

China

Products From Supplier